VESPARAYou cannot compare two scents in the same air.

AI-generated visual: seven freestanding cells woven from pale larch laths, each lit warmly from within, standing in a line down an empty concrete hall.

At a glance

Design thinking
Set the route to three cells, because fatigue is what destroys a comparison.
Problem
A fragrance counter puts every scent into one shared volume of air, so nothing after the third spray can be told apart.
Approach
We treated the counter’s failure as an air problem and gave every scent its own extracted volume.
Outcome
A concept study drawn to a production pack: a dimensioned plan, a section through a cell and the open questions.
Role
Self-initiated by Flygen. VESPARA is an invented brand: there was no client, no commission, and nothing was built.
What we designed
  • Spatial concept
  • Zoned plan and visitor journey
  • Materials, lighting and finishes
  • Brand application
  • Digital touchpoint
  • Plan, section and build sequence
  • Production questions
Platforms
  • Modular activation kit
  • Sealed envelope
  • One web touchpoint

The decision

Abandon the bottle wall and build separated air.

At a counter seven scents share one volume of air, so the second is smelled through the first. The kit is therefore seven cells, one scent each, Ø1 800 and 2.4 m high, assumed. The scent sits on a substrate in a well in a limestone block, never sprayed into the room, and every cell is doorless with an 800 mm offset baffle, so there is no straight-through air path.

The route is set, not browsed — and the card says why.

A free run through seven cells guarantees fatigue, and fatigue destroys a comparison.

  1. 01ThresholdThree questions make a card: three numbers, an order, and why
  2. 02Cell oneOne scent, one block, one light, about ninety seconds, alone
  3. 03ResetFiltered unscented air, water, two minutes, 4000 K at 400 lux
  4. 04Cell twoThe same ritual, a different volume of air
  5. 05ResetCooler and brighter than anything around it
  6. 06Cell threeThe last one on the card; the route does not continue
  7. 07The envelopeOne scent named, written by hand, sealed with wax

The plan, zone by zone.

Seven cells over roughly 18.9 × 5.0 m including the service corridor — about 95 m², assumed. Three cells is about 50 m².

  1. 01Threshold counter

    Sets the route; the one position that cannot be cut

    • 2.4 × 0.7 m, top at 1050 mm
    • At 45°, so the queue forms along the front
    • Route cards, pencils, staff on the inside face
    • Allergen and ingredient sheets, on paper
  2. 02Cell row

    One scent, one person, one volume of air

    • Ø1 800 internal clear, 100 mm wall, Ø2 000 out
    • 2.4 m internal, plus a 400 mm plenum: 2.8 m
    • 800 mm offset baffle, 900 mm clear, no door
    • Limestone block 300 × 300 × 1050, face at 760
    • 150 mm extract spigot at the top rear
    • About 6.1 m³ of air, cell to cell identical
    • Cell four: 1 000 mm entry, a fabric baffle
    • 1.5 m turning circle; intent, not a sign-off
  3. 03Aisle, waiting and reset

    In front of the row; it is also the escape route

    • 1.8 m aisle kept clear, widths checked per venue
    • Cell numbers at 2100 mm, read over heads
    • Three waiting positions opposite, not in front
    • Reset bench 2.4 × 0.8 m, in a bay off the aisle
    • No coffee beans: separated air and time instead
  4. 04Service corridor

    Behind the row; visitors never see into it

    • 1.2 m clear; 1.0 m where it is single-sided
    • 600 mm access door into the rear of each cell
    • 200 mm extract spine high level, substrate stock
  5. 05Lining and light

    Porous timber holds odour, so no raw ply inside

    • 3 mm powder-coated aluminium, warm off-white
    • Magnetic cleats: a tainted panel out in a minute
    • Raw birch ply only outside, where no scent sits
    • 2700 K at 80–120 lux, 3000 K spot on the block

The constraint

The plan rests on a landlord extract connection within 8 m.

Each cell is about 6.1 m³, so 6–10 air changes an hour is roughly 10–17 l/s, purged harder between visitors. All assumed, all for an M&E engineer. Without a connection the fallback is carbon-filtered recirculation per cell, which clears a volume less reliably: a compromise, named as one. It is the first question to a production partner.

The names are available anywhere; the sequence that produced them is not.

The activation exists to produce one object: a blotter card, one scent written on it by hand, sealed with wax at a 1.6 × 0.8 m table past the last cell. The seal carries a code that returns the three scents in the order they were smelled, the staff member’s one-line note, and the chosen one marked. That order is what reconstructs the decision three weeks later, in a shop.

Plan and section.

A visualisation proves it can be imagined; a drawing proves somebody has thought about building it. Two sheets, drawn by code in millimetres from the figures in this study — scripts/spatial/vespara.mjs — and marked indicative, not for construction. Drawing them corrected the study three times: the cell is a cylinder, not a 1.8 m square; its volume is 6.1 m³, not 7.8; and the configuration is seven cells, not three in 18 m². The cobalt numbers are the eleven brand marks, numbered as they are in the copy below.

Dimensioned general arrangement plan of the seven-cell configuration, 18 900 × 5 000: seven woven cylindrical cells of Ø2 000 at 2 150 centres between a 1 800 mm visitor aisle and a 1 200 mm service corridor, each with a 900 mm entry and an offset baffle, a threshold counter at 45°, a reset bench in its own bay and a choice table at the end, with the weave open area written under every cell.
01Sheet 01 · GA planGeneral arrangement, seven cells over 18.9 × 5.0 m. The weave under each cell runs 42 % open at one to 12 % at seven.
Section C–C through one cell: a Ø1 800 internal clear volume 2 400 mm high under a 400 mm sealed extract plenum, a 150 mm spigot into a 200 mm spine duct in the service corridor, make-up air entering through a low louvre beside the entry, and the limestone block on a 900 × 900 × 20 steel spreader plate, with the air path drawn as a dashed sweep from entry to top rear.
02Sheet 02 · Section C–CSection C–C. Air enters low at the entry and leaves at the top rear, so the sweep crosses the block rather than the doorway.

How it is assembled, and what it weighs.

Every figure here is an assumption written to start a conversation with an engineer, not a load schedule. A 255 kg block on a 300 × 300 base is 27.8 kN/m².

  1. 01Frame and skin

    Bolted, not welded; nothing is cut on site

    • 40 × 40 bolted aluminium box section
    • A base ring on adjustable feet, levelled first
    • Twelve verticals, three ring beams
    • A capped plenum box forms the top 400 mm
    • 70 × 9 raw birch ply laths, two helical layers
    • Woven to the open area set for that cell
    • Entry slot trimmed to 900 mm clear, no door
    • Cell number back-lit at 2 100 mm
  2. 02Block and floor loading

    The heaviest item, and a per-venue check

    • Limestone 300 × 300 × 1 050, about 255 kg
    • A 120 mm recessed well for the substrate
    • 27.8 kN/m² on its base; a mall floor takes 4–5
    • 900 × 900 × 20 spreader plate: 3.1 kN/m²
    • Skated in before the skin closes the cell
  3. 03The air path

    The whole reason the thing exists

    • 600 × 150 slot at the top rear of the plenum
    • 150 mm spigot, flex-ducted to a 200 mm spine
    • 400 × 100 make-up louvre at 150 mm, by the entry
    • Inline fan and attenuator, NR 35 in the aisle
    • A purge boost between visitors
  4. 04Power, water and data

    About 7 kW for seven cells, assumed

    • 3 × 16 A: lights and fans, bench, threshold till
    • 15 mm supply and 40 mm waste at the bench
    • Or a 25 l bunded unit where neither exists
    • No data in a cell: the code is a web page
  5. 05Programme, freight and trades

    Flygen has none of these trades in house

    • M&E first fix the day before the kit goes in
    • One day, three people; struck in four hours
    • Cases kept under 85 kg: a two-person lift
    • A 2 450 mm case needs a deep goods lift
    • 7.5 t truck with a tail lift per three cells
    • Blocks palletised, moved on skates
    • Fragrance freight: flashpoint limits apply
    • Flight cases and weight per case still to setOpen

An open mark is a figure a fabricator still has to set.

The mark is never drawn as a logo. It is only ever walked through.

Eleven brand marks, numbered here as they are on the sheets. The mark’s aperture is the cell opening at architectural scale, so a visitor passes through the logotype.

  1. 01Geometry and material

    Survives every photograph; cannot be removed

    • 1 · The mark’s aperture is the cell opening
    • 2 · The weave tightens cell by cell
    • 42 % open area down to 12 %, in 5 % steps
    • 3 · Cell numerals inlaid in brass, 90 mm, flush
    • 4 · Cell seven is the only coloured volume
  2. 02Numbered, never named

    7 · The first word is read at the very end

    • Nothing in the row carries a word
    • Cells are 1 to 7: brass underfoot, lit at 2 100
    • The route card gives numbers, not names
    • A name contaminates a comparison
  3. 03What a hand meets

    8 · One block, and not one handle in the kit

    • Limestone, honed and never polished
    • A 20 mm arris, cold to a palm
    • The well is 120 deep: no reaching the source
    • You smell the air, never the substrate
    • Doorless, so nothing is ever gripped
  4. 04Conduct and sound

    6, 9, 10 · The layers a competitor cannot photograph

    • No scent on anyone. None.
    • No scented laundry wash, no hand cream
    • One person, at the end, never at the start
    • No cell is entered while it is occupied
    • Never said: this one is our bestseller
    • Target NR 30 in a cell, NR 35 in the aisle
    • No music: a tune is a second comparison
  5. 05What leaves, and the one frame

    5, 11 · The brand in a pocket, and the photograph

    • A sealed envelope, waxed in front of you
    • Seal die: the mark at 18 mm, its only small use
    • Eye at 1 600, down the row from the threshold
    • Drawn on sheet 01; the bench’s 4000 K goes off

What a landlord, a fire officer and a fabricator still have to answer.

A concept study can say what it has not resolved. Flygen designs to a production pack, does not fabricate and does not quote a build.

  1. D01

    Will a landlord permit an enclosed, roofed, single-occupancy cell?

    Context
    Each cell is a 6.1 m³ volume with no door, one person inside, a 900 mm opening and a 900 mm return wall.
    Options
    • Roofed cells as drawn, with detection in every cell
    • An open-topped variant, with the extract re-planned
    Decision
    Open. Occupancy, detection, sightlines and whether a roof is permitted at all go to the landlord’s fire officer.
    Why
    An open-topped variant changes the extract strategy from the ground up, so the answer changes the drawing and not only the paperwork.
  2. D02

    Raw birch ply in a shopping centre: what surface-spread class is required?

    Context
    The exterior of every cell is raw birch ply lath, and reading as honest timber from the aisle is the whole material argument.
    Options
    • Untreated, if the venue accepts it
    • An intumescent treatment to the required class
    Decision
    Open. Treatment would change the colour and the touch of the skin, which is a brand question as well as a fire one.
    Why
    Better to hear it from the fire officer before a weaver quotes the whole kit than after it is delivered.
  3. D03

    How long does a lining panel last before it holds odour?

    Context
    The lining is replaceable by design, but nothing tells us the interval over a run, or how substrates are disposed of between venues.
    Decision
    Open. Settled with the fabricator and a materials test, not asserted here.
    Why
    Cross-contamination over a run would undo the one thing the plan exists to deliver: air with only one scent in it.